CAR WASH SERVICE LIFT LAHORE

by Unknown author

4/0-4/0-4/0 Aluminum SEU Service Entrance Cable 600V (205 Amp Rated)

HomeView All ListingsStore PoliciesNewsletterFeedbackContact Us Store Categories Aluminum URD Cable Aluminum Service Drop Cable Aluminum XHHW-2 Wire Aluminum XLP USE-2 Aluminum SER Alpha Wire Belden Cable Bus Drop Cable Copper SER Copper THHN THWN-2 Wire Copper XHHW-2 Wire Copper XLP USE-2 Diesel Locomotive Cable Festoon Cable Fire Alarm Cable High Temperature Wire Jumper Cable Type G & GG-C Thermostat Cable SOOW Power Cable NM-B Wire Security Fire Alarm Cable SIS Switchboard Wire Solar Photovoltaic PV Wire Stage Lighting Cable Submersible Pump Cable Tray Cable Type W Power Cable UF-B Cable Welding Cable 4/0-4/0-4/0 Aluminum SEU Service Entrance Cable 600V Click Thumbnails to Enlarge APPLICATION • 4/0-4/0-4/0 Aluminum SEU Primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panel board. SEU can also be used in certain branch circuits as permitted by the National Electric Code. Maximum Operating Temperature is not to exceed 90°C in wet or dry locations. Voltage rating is 600 volts. CONDUCTOR • Compact Strand Soft drawn 8000 Series Aluminum Conductor, per ASTM B-801 INSULATION • Cross-Linked Polyethylene (XLPE) Insulation ASSEMBLY • Phase Conductor(s) Surrounded by a Concentrically Applied Neutral and Binder Tape JACKET • Gray Sunlight Resistance Polyvinyl Chloride (PVC) Jacket. STANDARDS • UL 44: Thermoset-Insulated Wires and Cables • UL 854: Standard for Service-Entrance Cables • ASTM B-800, B-801 • Federal Specifications J-C-30B • National Electric Code PRODUCT SPECIFICATIONS Insulated Conductor Size AWG 4/0 Bare Ground Conductor Size AWG 4/0 Outside Dimensions (inches) 0.878 x 1.462 Ampacity at 90°C 205 Amps Weight (lbs/1000ft) 765 CUT TO LENGTH Looking for Longer lengths or Cut to Length? Please feel free to contact us. OTHER VALUE ADDED SERVICES • Expedited Shipping • Cut to Length Paralleling • Color Striping & Dyeing • Reel Lagging • Special Labeling & Packages Shipping ***Free shipping on most orders. Need the wire fast? Ask about our expedited shipping to get it to you on time. Signature required for all deliveries. Please note eBay’s delivery dates are only estimates actual delivery dates may be faster or longer, please message us for exact delivery times.*** Payment & Returns ***All returns must be made within 30 days from the date of purchase or they will not be accepted. Nassau National Cable does not cover re-delivery fees, extraneous shipping expenses or change of address fees after shipping*** About Nassau National Cable (disclaimer: these images of wire in no way reflect the product being sold and are for aesthetic purposes only) We have been in business for over 60 years and are family owned and operated. We have been on the inc 5000 in 2014, 2015, and 2016 as one of the fastest growing privately owned companies. We look forward to serving you. Some of our customers are shown below: Home View All Listings Store Policies Feedback Contact Us

by Unknown author

2/0-2/0-2/0-1 Aluminum Mobile Home Feeder Direct Burial Cable (150 Amp) 600V

HomeView All ListingsStore PoliciesNewsletterFeedbackContact Us Store CategoriesAluminum URD Cable Aluminum Service Drop Cable Aluminum XHHW-2 Wire Aluminum XLP USE-2 Aluminum SER Alpha Wire Belden Cable Bus Drop Cable Copper SER Copper XHHW-2 Wire Copper XLP USE-2 Diesel Locomotive Cable Festoon Cable Fire Alarm Cable High Temperature Wire Jumper Cable Type G & GG-C Thermostat Cable SOOW Power Cable NM-B Wire Security Fire Alarm Cable SIS Switchboard Wire Solar Photovoltaic PV Wire Stage Lighting Cable Submersible Pump Cable THHN THWN-2 Wire Tray Cable Type W Power Cable UF-B Cable Welding Cable 2/0-2/0-2/0-1 Aluminum Mobile Home Feeder Direct Burial Cable 600V Click Thumbnails to Enlarge APPLICATION • 2/0-2/0-2/0-1 Mobile Home Feeder cable is designed for mobile homes as a service entrance cable. The cable is sunlight resistant and is approved for use in accordance with the recommendations of the National Electric Code in raceways and underground installations. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts. CONDUCTOR • Compact Stranded AA-8000 Series Aluminum Conductor, per ASTM B-800 & B-801 INSULATION • Type USE-2/RHH/RHW-2 Cross-Linked Polyethylene (XLP) insulation. ASSEMBLY • It has Four Conductors including two phase conductors, one neutral and one ground. The neutral conductor is identified by three continuous white longitudinal stripes. The grounding conductor is identified by total green surface coating STANDARDS • UL 44 for Type RHH or RHW-2 • UL 854 for Type USE-2 Insulated Wire • National Electrical Code NFPA 70 (NEC) • ICEA S-95-658/NEMA WC-70 PRODUCT SPECIFICATIONS Phase Conductor Size 2/0 AWG Neutral Conductor Size 2/0 AWG Ground Conductor Size 1 AWG Insulation Thickness (inches) 0.080 Overall Diameter (inches) 1.301 Ampacity 150 Amps Weight (Lbs/1000ft) 660 Shipping Need the wire fast? Ask about our expedited shipping to get it to you on time. Signature required for all deliveries. Please note eBay’s delivery dates are only estimates actual delivery dates may be faster or longer, please message us for exact delivery times.*** Payment & Returns ***All returns must be made within 30 days from the date of purchase or they will not be accepted. Nassau National Cable does not cover re-delivery fees, extraneous shipping expenses or change of address fees after shipping*** Feedback Feedback will be left as soon as feedback is left for us.

by Unknown author

18/4 Shielded Tray Cable TFFN/PVC TC-ER VNTC Power Control Wire Black 600V

HomeView All ListingsStore PoliciesNewsletterFeedbackContact Us Store Categories Aluminum URD Cable Aluminum Service Drop Cable Aluminum XHHW-2 Wire Aluminum XLP USE-2 Aluminum SER Alpha Wire Belden Cable Bus Drop Cable Copper SER Copper XHHW-2 Wire Copper XLP USE-2 Diesel Locomotive Cable Festoon Cable Fire Alarm Cable High Temperature Wire Jumper Cable Type G & GG-C Thermostat Cable SOOW Power Cable NM-B Wire Security Fire Alarm Cable SIS Switchboard Wire Solar Photovoltaic PV Wire Stage Lighting Cable Submersible Pump Cable THHN THWN-2 Wire Tray Cable Type W Power Cable UF-B Cable Welding Cable 18/4 Shielded Tray Cable TFFN/PVC TC-ER VNTC Power Control Wire Black 600V Click Thumbnails to Enlarge APPLICATION • 18/4 Shielded Tray Cable Primarily used for power, control, signal, communication and lighting circuits in commercial and industrial environments. Suitable for installation in cable trays, supported by messenger wire in open air, raceways, channels, conduits and ducts. Approved for direct burial and outdoors in cable trays where sunlight resistant is required. Also may be installed in wet or dry locations or in areas exposed to chemicals and oils. CONDUCTOR • Fully Annealed Bare Copper Class B Compressed Strand per ASTM B-3 and ASTM B-8 INSULATION • Heat and moisture resistant Polyvinylchloride (PVC) per UL 66 • Clear Polyamide (Nylon) jacket per UL 66. SHIELD • 100% Coverage Spiral wound Aluminum-Mylar Tape Shield, with a 7 Strand Tinned Flexible Copper Drain Wire JACKET • Flame and Sunlight Resistant Black PVC rated 90°C wet or dry per UL 1277 STANDARDS • UL 66, UL 1277 • UL1685 and IEEE 383 70,000 BTU Vertical Flame Test • UL Listed to IEEE1202 and CSA FT4 70,000 BTU Flame Test • UL Listed as TC-ER (Exposed Run) per UL Standard 1277 and used in accordance with NEC for 3 or more conductors • Approved for Class 1 or 2, Division 2 industrial hazardous locations per NEC • Rated 90°C wet or dry • Meets cold bend test at -25°C • ICEA S-95-658, ICEA S-73-532 PRODUCT SPECIFICATIONS Size AWG18 Number of Conductors4 Number of Strands7 Drain Wire Size AWG20 Insulation Thickness (inches)0.015 Nylon Thickness (inches) 0.004 Jacket Thickness (inches) 0.045 Overall Diameter (inches)0.360 Weight (lbs/1000ft)70 HAVE A LARGE ORDER OVER $5000? ASK US IF WE CAN DO BETTER ON THE PRICE. Shipping ***Free shipping on most orders. Need the wire fast? Ask about our expedited shipping to get it to you on time. Signature required for all deliveries. Please note eBay’s delivery dates are only estimates actual delivery dates may be faster or longer, please message us for exact delivery times.*** Payment & Returns ***All returns must be made within 30 days from the date of purchase or they will not be accepted. Nassau National Cable does not cover re-delivery fees, extraneous shipping expenses or change of address fees after shipping***

by Unknown author

4/0-4/0-4/0-2/0 Aluminum SER Service Entrance Cable 600V Lengths 25′ to 1000′

4/0-4/0-4/0-2/0 Aluminum SER Service Entrance Cable Lengths 25 Feet to 1000 Feet Click Thumbnails to Enlarge APPLICATION – 4/0-4/0-4/0-2/0 Aluminum SER cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature is not to exceed 90°C in wet locations.Voltage rating is 600 volts. CONDUCTOR – Aluminum SER cable has a compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801 INSULATION – Aluminum SER cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with a bare aluminum alloy ground. For color code, see table Bin technical section. JACKET – Aluminum SER cable has a gray sunlight resistance polyvinyl chloride (PVC) jacket. STANDARDS – Ampacities based on National Electric Code, 2005 edition, section 310-15 – 60°C when terminated to equipment for circuits rated 100amps or less or marked for 14ga through 1ga conductors – 70°C when terminated to equipment for circuits rated over 100amps or marked for conductors larger than 1ga – 90°C wet or dry locations For dwelling units, conductors shall be permitted at listed Ampacities to be utilized as 120/240 volt, 3-wire, single phase service conductors that supply the total load – UL 44 DISCLAIMER – Picture May Not Represent Actual Cable and is Only Used As a Representation Please Refer to The Specifications for Product Accuracy. PRODUCT SPECIFICATIONS Size AWG 4/0 Number of Strands 18 Bare Ground Conductor Size AWG 2/0 Nominal Overall Diameter (inches) 1.421 Allowable Ampacities at 75°C 180 Amps Allowable Ampacities at 90°C 205 Amps Weight (lbs/1000ft) 985 HAVE A LARGE ORDER OVER $5000? ASK US IF WE CAN DO BETTER ON THE PRICE. CUT TO LENGTH Looking for Custom Lengths? Please feel free to contact us, We can do all cut to length. OTHER VALUE ADDED SERVICES • Expedited Shipping • Cut to Length Paralleling • Color Striping & Dyeing • Reel Lagging • Special Labeling & Packages Shipping ***Free shipping on most orders. Need the wire fast? Ask about our expedited shipping to get it to you on time. Signature required for all deliveries. Please note eBay’s delivery dates are only estimates actual delivery dates may be faster or longer, please message us for exact delivery times.*** Payment & Returns ***All returns must be made within 30 days from the date of purchase or they will not be accepted. Nassau National Cable does not cover re-delivery fees, extraneous shipping expenses or change of address fees after shipping*** Feedback Feedback will be left as soon as feedback is left for us.

by Unknown author

6 AWG Copper THHN THWN-2 Building Wire 600V Lengths 75 Feet to 1000 Feet

HomeView All ListingsStore PoliciesNewsletterFeedbackContact Us Store Categories Metal Clad Cable UF-B Portable Cord SOOW SJOOW THHN/TFFN Machine Tool Wire Electronic Wire Aluminum XLP USE Direct Burial Telephone Cable Miscellaneous Odds & Ends Control Cable BX Cable Switchboard Cable Copper Building Wire XLP Copper Building Wire XHHW PVC Twist Sub Pump Cable No GD PVC Twist Sub Pump Cable W/G Flat Neoprene Pump Cable W/G Flat (2) JKT Pump Cable No GD Flat (2) JKT Pump Cable W/G Service Entry Cable Romex NM-B Diesel Locomotive Cable Type W Power Cable Welding Cable Aluminum URD Direct Burial Aluminum XHHW Conductor Aluminum Service Drop Overhead Aluminum Bare ACSR Aluminum SER & SEU 6 AWG Copper THHN THWN-2 Building Wire 600V Lengths 75 Feet to 1000 Feet Click Thumbnails to Enlarge APPLICATIONS – 6 AWG THHN THWN-2 Copper conductors are primarily used in conduit and cable trays, when approved, for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electric Code. THHN applications are suitable for use in dry locations only at temperatures not to exceed 90°C. CONDUCTORS – Stranded soft drawn copper, per ASTM. INSULATION – Heat and moisture resistant colored polyvinyl chloride PVC insulation, with a clear nylon (polyamide) or UL-listed equal jacket, which provides abrasion resistance. STANDARDS – UL 83, UL 62 – UL VW-1 – Size 1/0 & larger suitable for cable tray use – MTW per UL 1063 – ASTM B-1, B-3, B-8 – Federal Spec J – C – 30B DISCLAIMER – Picture May Not Represent Actual Cable and is Only Used as a Representation Please Refer to The Specifications for Product Accuracy. PRODUCT SPECIFICATIONS Size AWG 6 No. of Strands 19 Insulation Thickness (inches) 0.030 Nylon Thickness (inches) 0.005 Overall Diameter (inches) 0.250 Weight (lbs/1000ft) 98 Shipping ***Free shipping on most orders. Need the wire fast? Ask about our expedited shipping to get it to you on time. Signature required for all deliveries. Please note eBay’s delivery dates are only estimates actual delivery dates may be faster or longer, please message us for exact delivery times.*** Payment & Returns ***All returns must be made within 30 days from the date of purchase or they will not be accepted. Nassau National Cable does not cover re-delivery fees, extraneous shipping expenses or change of address fees after shipping*** Feedback Feedback will be left as soon as feedback is left for us.

by Unknown author

Cockle 2-2-4 ACSR Triplex Aluminum Overhead Service Drop Cable (150 Amp) 600V

HomeView All ListingsStore PoliciesNewsletterFeedbackContact Us Store Categories Aluminum URD Cable Aluminum Service Drop Cable Aluminum XHHW-2 Wire Aluminum XLP USE-2 Aluminum SER Alpha Wire Belden Cable Bus Drop Cable Copper SER Copper XHHW-2 Wire Copper XLP USE-2 Diesel Locomotive Cable Festoon Cable Fire Alarm Cable High Temperature Wire Jumper Cable Type G & GG-C Thermostat Cable SOOW Power Cable NM-B Wire Security Fire Alarm Cable SIS Switchboard Wire Solar Photovoltaic PV Wire Stage Lighting Cable Submersible Pump Cable THHN THWN-2 Wire Tray Cable Type W Power Cable UF-B Cable Welding Cable Cockle 2-2-4 ACSR Triplex Aluminum Overhead Service Drop Cable 600V Click Thumbnails to Enlarge APPLICATION • Cockle 2-2-4 Triplex Aluminum Service Drop cable is designed for use to supply power from utility lines to the consumer weather head. For service at 600 volts or lower (phase to phase) at a conductor temperature of 90°C maximum for cross linked insulation or 75°C maximum for polyethylene insulation. CONDUCTOR • Compressed 1350-H19 series aluminum conductor MESSENGER • ACSR Bare Neutral Messenger INSULATION • Black cross linked polyethylene (XLP) insulation STANDARDS • ASTM B-230 Aluminum 1350–H19 Wire for Electrical Purposes • ASTM B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors • ASTM B-232 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) • ASTM B-399 Concentric-Lay-Stranded Aluminum-Alloy 6201-T81 Conductors • ICEA S-76-474 Neutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulation Rated 600 Volts • RUS Accepted PRODUCT SPECIFICATIONS Size AWG (Phase Conductors)2 Number of Strands7 Size AWG (Bare Neutral Messenger)4 Insulation Thickness (inches)0.045 Overall Diameter (inches) 0.800 Ampacity at 90°C150 Amps Weight (Lbs/1000ft)225 HAVE A LARGE ORDER OVER $5000? ASK US IF WE CAN DO BETTER ON THE PRICE. Shipping ***Free shipping on most orders. Need the wire fast? Ask about our expedited shipping to get it to you on time. Signature required for all deliveries. Please note eBay’s delivery dates are only estimates actual delivery dates may be faster or longer, please message us for exact delivery times.*** Payment & Returns ***All returns must be made within 30 days from the date of purchase or they will not be accepted. Nassau National Cable does not cover re-delivery fees, extraneous shipping expenses or change of address fees after shipping***

by Unknown author

1-1-1-3 Copper SER Service Entrance Cable PVC Jacket Gray (150 Amp) 600V

HomeView All ListingsStore PoliciesNewsletterFeedbackContact Us Store Categories Aluminum URD Cable Aluminum Service Drop Cable Aluminum XHHW Aluminum XLP USE Aluminum SER Alpha Wire Belden Cable Bus Drop Cable Copper SER Copper XHHW Copper XLP USE Diesel Locomotive Cable Festoon Cable Fire Alarm Cable High Temperature Wire Jumper Cable Mining Cable Type G & GG-C Thermostat Cable Power Power Cable NM-B Wire Security Fire Alarm Cable SIS Switchboard Wire Solar Photovoltaic PV Wire Stage Lighting Cable Submersible Pump Cable THHN THWN-2 Copper Wire Tray Cable Type W Power Cable UF-B Cable Welding Cable 1-1-1-3 Copper SER Service Entrance Cable PVC Jacket 600V Lengths 10 Feet to 1000 Feet Click Thumbnails to Enlarge APPLICATION – 1-1-1-3 Copper SER Service Entrance Cable is primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panel board; however, the cable may be used in all applications where Type SE cable is permitted. SER may be used in wet or dry locations at temperatures not to exceed 90°C. Voltage rating is 600 volts. CONSTRUCTION – Three copper conductors, stranded and insulated with heat and moisture resistant, chemically crosslinked polyethylene (type XHHW-2). Phase identified and cabled together with bare copper ground conductor. Cable core covered with flame retardant binder tape and overall grey PVC jacket. STANDARDS – Federal Specification A-A-59544 – National Electrical Code, NFPA 70. 2011 Edition – RoHS Compliant – Sunlight Resistant DISCLAIMER – Picture May Not Represent Actual Cable and Is Only Used As A Representation Please Refer to The Specifications For Product Accuracy. PRODUCT SPECIFICATIONS Size AWG 1 Number of Strands 19 Grounding Conductor Size AWG 3 Insulation Thickness (inches) 0.055 Jacket Thickness (inches) 0.030 Overall Diameter (inches) 1.132 Ampacity (30°C ambient) 90°C Wet/Dry 150 Amps Weight (lbs/1000ft) 1115 CUT TO LENGTH Looking for Custom Lengths? Please feel free to contact us, We can do all cut to length. OTHER VALUE ADDED SERVICES • Expedited Shipping • Cut to Length Paralleling • Color Striping & Dyeing • Reel Lagging • Special Labeling & Packages Shipping ***Free shipping on most orders. Need the wire fast? Ask about our expedited shipping to get it to you on time. Signature required for all deliveries. Please note eBay’s delivery dates are only estimates actual delivery dates may be faster or longer, please message us for exact delivery times.*** Payment & Returns ***All returns must be made within 30 days from the date of purchase or they will not be accepted. Nassau National Cable does not cover re-delivery fees, extraneous shipping expenses or change of address fees after shipping*** Feedback Feedback will be left as soon as feedback is left for us.